K Type Thermocouple Cable Resistance
The type k is the most common type of thermocouple.
K type thermocouple cable resistance. It s inexpensive accurate reliable and has a wide temperature range. Type k thermocouple reference tables type j reference tables all major thermocouple reference tables reotemp instrument corporation 10656 roselle street san diego ca 92121 phone. The type k is commonly found in nuclear applications because of its relative radiation hardness. We have an ex stock range of type k thermocouple cables with pvc pfa fibreglass silicone rubber and kapton insulation.
3 x 5894 1 7682 ohms 20 x 1466 2 932 ohms total 4 7002 ohms note. This may be an immersion sensor a surface sensor wire or another style of sensor or cable. Sharon corbett created date. Type k thermocouple nickel chromium nickel alumel.
Type k thermocouple wire coating. The thermocouple wire or cable is used to manufacture thermocouple probes in order to sense temperature using the point of cold junction compensation cjc end. Delivery is available next day if required and all our type k thermocouple cables are to iec 60584 3 ansi spec also available. What is external resistance to my instrument if i use a 20 guage chromel alu mel thermocouple 3 feet long and 14 guage chromel alumel lead wire 20 feet in length.
Type k temperature. Maximum continuous temperature is around 1 100c. A 1 4 inch wide sheathed ungrounded type k thermocouple responds to temperature changes in water in about 2 25 seconds. A type k thermocouple refers to any temperature sensor containing chromel and alumel conductors that meets the output requirements as stated in ansi astm e230 or iec 60584 for type k thermocouples.
Coated wires display different response times in different media. On the other side as it has been explain in this other article a thermocouple is a sensor for measuring temperature that consists of two dissimilar metals that are joined together at the sensing end. Thermocouple wire size and resistance table resistance in ohms per double foot at 68 f. Always measure the resistance of the thermocouple out of the application so the emf output is not in conflict with the resistance meter.
Type s and r utillize extension lead wire type copper copper 11. Ohms per double feet long lead wire runs or the use of analog based instrumentation make conductor resistance an important consideration in selecting the wire gauge best suited for your application. Diameter inches type k chromel alumel to print right click or press ctrl p. 540 22 350 22 393 22 435 22 478 22 521 22 563 22 606 22 649 22 691 22 734 22 776 540 k thermocouple reference tables type monograph 175 revised to its 90.